Innovation and development of stent retrievers in acute ischemic stroke
en-GBde-DEes-ESfr-FR

Innovation and development of stent retrievers in acute ischemic stroke

26/12/2025 Frontiers Journals

Acute ischemic stroke caused by large-vessel occlusion demands rapid restoration of cerebral blood flow, and stent retrievers have evolved from simple helical wires into sophisticated multi-layer nitinol devices that achieve recanalization rates exceeding 80 %. The first-generation MERCI system introduced the concept of endovascular clot extraction, yet its 48 % recanalization rate and 7.8 % symptomatic hemorrhage risk underscored the need for better wall apposition, thrombus engagement, and distal protection. Second-generation closed-loop designs such as Solitaire and Trevo doubled the rate of favorable three-month outcomes by combining self-expanding radial force with full-length radiopacity, enabling operators to visualize device–thrombus interaction and limit passes. Third-generation tools now integrate dual-layer baskets, adjustable radial force, and distal trapping zones that capture fragmented thrombi while reducing endothelial trauma, pushing first-pass effect toward 60 % and cutting procedure time to under 45 min in experienced centers.
Contemporary engineering focuses on four complementary directions: finer mesh geometry that embeds fibrin-rich clots, hybrid open–closed loop architectures that balance flexibility with fixation force, surface coatings that decrease thrombogenicity, and intelligent handles that allow real-time diameter modulation. Solitaire X incorporates a tapered distal segment and reduced delivery profile, increasing first-pass mTICI 2c/3 rates to 66% compared with 51% for Solitaire FR while lowering subarachnoid hemorrhage from 9% to 4%. Trevo NXT ProVue adds hydrophilic polymer to the delivery wire, cutting friction by 30% and enabling navigation through tortuous carotid siphons without exchange-length microcatheters, a benefit that translates into 17 min shorter groin-to-reperfusion intervals in multicenter registries. EmboTrap III widens the proximal entry window to 4.5 mm while tapering the distal basket to 2 mm, creating a funnel that guides thrombus into a five-strut cage; early series report 42% first-pass effect and 7 % embolization to new territories, half the rate observed with earlier platforms.
Safety refinements parallel efficacy gains. APERIO Hybrid interlaces radiopaque double-helix markers with alternating closed and open loops, distributing radial force along 24 contact points and reducing intimal stress; hemorrhagic complications fell from 12% to 5% without loss of recanalization power. Tigertriever 13 couples a 0.013-inch delivery wire to a manually adjustable braid, allowing operators to cinch the device around resistant clots and withdraw under continuous aspiration; distal vessel perforation rates remain below 2% even in M2–M3 segments where traditional self-expanding stents generate excessive outward force. Material science contributes nitinol alloys enriched with titanium or tantalum surface layers that resist corrosion and limit inflammatory signaling, while laser-cut tubing permits cell sizes as small as 200 µm—small enough to retain platelet-rich emboli yet large enough to preserve perforator patency.
Looking forward, integration of artificial intelligence, micro-sensors, and robotic assistance promises procedural standardization. Algorithms trained on thousands of angiographic runs predict thrombus length and consistency from initial contrast stagnation patterns, guiding device selection before microcatheter passage. Flexible force sensors embedded in the distal wire transmit real-time tension curves to a console, alerting operators to impending vessel rupture when radial stress exceeds 0.4 N. Shape-memory polymers that soften at 33 °C and regain rigidity at 37 °C are being woven into 0.017-inch profiles, enabling trans-distal access through fetal posterior communicating arteries while expanding to 3.5 mm once deployed. Biodegradable magnesium scaffolds coated with sirolimus-eluting matrices undergo controlled dissolution over six weeks, potentially eliminating the need for dual antiplatelet therapy in patients with coincidental intracranial stenosis.
Despite impressive technological strides, global implementation remains uneven. High-income centers report door-to-reperfusion times under 60 min, yet rural districts across Asia and Africa lack catheter laboratories, trained neuro-interventionalists, and affordable devices. Manufacturing costs for third-generation retrievers exceed US $1,500 per unit, ten-fold the price of a standard aspiration catheter. Public–private partnerships are piloting reusable sterilization protocols and tiered pricing models that could cut expenses by 40 %. Tele-stroke networks linked to 5-G robotic arm systems now allow operators in Beijing to manipulate foot pedals in Nairobi with 50-ms latency, achieving recanalization rates within 5% of on-site benchmarks. As randomized trials extend the therapeutic window to 24 h using perfusion mismatch criteria, next-generation stent retrievers will need to balance ultra-distal deliverability with rapid exchange capability, ensuring that patients who present late or transfer from primary centers still benefit from the evolution of clot extraction technology.
DOI:10.1007/s11684-025-1160-4
Attached files
  • Fig1 The pathogenesis of AIS
26/12/2025 Frontiers Journals
Regions: Asia, China, North America, United States
Keywords: Science, Life Sciences

Disclaimer: AlphaGalileo is not responsible for the accuracy of content posted to AlphaGalileo by contributing institutions or for the use of any information through the AlphaGalileo system.

Testimonials

For well over a decade, in my capacity as a researcher, broadcaster, and producer, I have relied heavily on Alphagalileo.
All of my work trips have been planned around stories that I've found on this site.
The under embargo section allows us to plan ahead and the news releases enable us to find key experts.
Going through the tailored daily updates is the best way to start the day. It's such a critical service for me and many of my colleagues.
Koula Bouloukos, Senior manager, Editorial & Production Underknown
We have used AlphaGalileo since its foundation but frankly we need it more than ever now to ensure our research news is heard across Europe, Asia and North America. As one of the UK’s leading research universities we want to continue to work with other outstanding researchers in Europe. AlphaGalileo helps us to continue to bring our research story to them and the rest of the world.
Peter Dunn, Director of Press and Media Relations at the University of Warwick
AlphaGalileo has helped us more than double our reach at SciDev.Net. The service has enabled our journalists around the world to reach the mainstream media with articles about the impact of science on people in low- and middle-income countries, leading to big increases in the number of SciDev.Net articles that have been republished.
Ben Deighton, SciDevNet

We Work Closely With...


  • e
  • The Research Council of Norway
  • SciDevNet
  • Swiss National Science Foundation
  • iesResearch
Copyright 2025 by AlphaGalileo Terms Of Use Privacy Statement