Engineered simplicity: new microfluidic device offers rapid kidney health check
en-GBde-DEes-ESfr-FR

Engineered simplicity: new microfluidic device offers rapid kidney health check

27.05.2025 TranSpread

Chronic kidney disease (CKD) affects over 800 million people globally and is often diagnosed too late for effective intervention. Early detection depends on accurate measurement of biomarkers such as creatinine and the urine albumin-to-creatinine ratio (uACR). While urine testing is non-invasive and informative, standard methods are time-consuming, costly, and require specialized facilities. Existing point-of-care devices offer convenience but remain prohibitively expensive or technically complex for many users. As such, there is an urgent need for a robust, affordable, and easy-to-use platform to measure urinary creatinine with clinical precision. Due to these challenges, new approaches are needed to develop accessible diagnostic tools for CKD screening and monitoring.

Researchers at the University of Manitoba, in collaboration with clinical and engineering partners, have developed a low-cost, passive microfluidic device for urine creatinine testing. Published (DOI: 10.1038/s41378-025-00880-z) on April 2, 2025, in Microsystems & Nanoengineering, the study details the design, fabrication, and validation of the "uCR-Chip." This device uses a color-based Jaffe reaction and a pressure-balanced flow system to deliver fast, stable measurements. By eliminating the need for external pumps or electricity, the uCR-Chip paves the way for affordable, decentralized kidney function testing.

The uCR-Chip integrates two key innovations: a passive 2-phase pressure compensation (2-PPC) flow system and a microfluidic channel network designed for a precise 1:5 mixing ratio between urine and reagent. This setup ensures consistent chemical reactions and rapid stabilization of the colorimetric signal. Using the Jaffe reaction, which produces an orange complex when creatinine interacts with picric acid in alkaline conditions, the chip enables quantifiable optical readings via a USB microscope platform. Signal stabilization is achieved within 7 minutes, and the chip maintains detection stability for over 30 minutes—a significant improvement over conventional assays. Technical validation demonstrated a dynamic linear detection range up to 40 mM and a low detection limit of 0.521 mM, covering the full clinical range. Compared with commercial point-of-care systems, the uCR-Chip showed comparable or better accuracy and less interference from artificial urine matrices. Additionally, the optimized lenticular observation window with a flow diverter enhances signal uniformity and shortens fill time. Fabricated using dry film lithography for high precision, the device is both scalable and reproducible. Together, these features make the uCR-Chip an attractive platform for portable diagnostics.

“Our goal was to create a diagnostic tool that is as easy to use as a glucose test strip, but with the accuracy of a lab-based creatinine assay,” said co-senior author Dr. Francis Lin. “The uCR-Chip meets that need by combining microfluidic precision with user-friendly design. It has the potential to transform how we detect and manage kidney disease, especially in under-resourced settings.” Dr. Lin emphasized the device’s affordability and scalability as key advantages for widespread public health deployment.

Beyond CKD screening, the uCR-Chip offers a broader platform for real-time health monitoring in diverse scenarios, from sports medicine to maternal care and drug testing. The researchers envision integrating this chip with a similar urine albumin microfluidic device for simultaneous uACR measurement, a crucial marker for kidney damage. The design also lends itself to future upgrades using enzymatic assays or fluorescence-based detection for improved specificity. With its compact, low-cost, and electricity-free format, the uCR-Chip represents a major step toward equitable, point-of-care diagnostics tailored to both clinical and home environments.

###

References

DOI

10.1038/s41378-025-00880-z

Original Source URL

https://doi.org/10.1038/s41378-025-00880-z

Funding Information

This study was supported by a Sponsored Research Agreement between the University of Manitoba and My Health Logic, Inc. (a subsidiary of Marizyme, Inc.).

About Microsystems & Nanoengineering

Microsystems & Nanoengineering is an online-only, open access international journal devoted to publishing original research results and reviews on all aspects of Micro and Nano Electro Mechanical Systems from fundamental to applied research. The journal is published by Springer Nature in partnership with the Aerospace Information Research Institute, Chinese Academy of Sciences, supported by the State Key Laboratory of Transducer Technology.

Paper title: A passive flow microreactor for urine creatinine test
Angehängte Dokumente
  • a Schematic illustration of the uCR-Chip showing the reagent inlet, sample inlet, observation window (OW), and outlet. The notation L and 5L indicate the channel length from the reagent inlet and the sample inlet channel, respectively, with a ratio of 1:5. The mixing channel originates from the intersection of the two flows, followed by the reaction channel before reaching the OW. b The COMSOL Multiphysics simulation of the flow mixing on the uCR-Chip. Rapid mixing is shown by the color gradient in the mixing channel followed by uniform color of the diluted concentration in the remaining reaction channel. Controlled mixing at 1:5 ratio is illustrated in the zoom-in figure. c Experimental testing of the mixing on the uCR-Chip using food color dyes. The rapid mixing is shown by quick transition to the green color. Controlled mixing at the 1:5 ratio is illustrated in the zoom-in figure. d Illustration of a USB microscope-based colorimetric signal reading system.
27.05.2025 TranSpread
Regions: North America, United States, Canada
Keywords: Applied science, Nanotechnology, Technology, Science, Chemistry

Disclaimer: AlphaGalileo is not responsible for the accuracy of content posted to AlphaGalileo by contributing institutions or for the use of any information through the AlphaGalileo system.

Referenzen

We have used AlphaGalileo since its foundation but frankly we need it more than ever now to ensure our research news is heard across Europe, Asia and North America. As one of the UK’s leading research universities we want to continue to work with other outstanding researchers in Europe. AlphaGalileo helps us to continue to bring our research story to them and the rest of the world.
Peter Dunn, Director of Press and Media Relations at the University of Warwick
AlphaGalileo has helped us more than double our reach at SciDev.Net. The service has enabled our journalists around the world to reach the mainstream media with articles about the impact of science on people in low- and middle-income countries, leading to big increases in the number of SciDev.Net articles that have been republished.
Ben Deighton, SciDevNet
AlphaGalileo is a great source of global research news. I use it regularly.
Robert Lee Hotz, LA Times

Wir arbeiten eng zusammen mit...


  • e
  • The Research Council of Norway
  • SciDevNet
  • Swiss National Science Foundation
  • iesResearch
Copyright 2025 by DNN Corp Terms Of Use Privacy Statement